3.1.2.7 Electricity and Electrical System in A Factory

Details
No. List of Laws Laws
2 Issues of Occupational Safety, Health And Environment ActB.E. 2554
4 Issues of Factory Act B.E. 2535
2 Issues of Other Act
1 The second-type entrepreneur of the factory business and the third-type entrepreneur of the factory business shall have drawing plan showing the installation of electrical system in the factory as actually built (as-built drawing) and particulars of the drawing; in such drawing, there shall be certification of engineers or other persons as specified by the cabinet as published in the Government Gazette.The entrepreneur of the factory business shall keep such drawing for the inspection by official. [1],[2],[3]
2 The entrepreneur of the factory business shall use material, equipment, and components of the electrical system in the factory which is characterized by Industrial Products Standard as specified by law on Industrial Product Standard or other accepted standards with the certification of engineers or other persons as specified by the cabinet as published in the Government Gazette. [1],[2],[3]
3 In using electrical sytem in the factory, the entrepreneur of the factory business shall take actions to be under the academic principle, or accepted standard or under criteria and other methods as specified by the Cabinet by publishing in the Government Gazette. [1],[2],[3]
4 The entrepreneur of the factory business shall provide for inspection of electrical system and safety certification of electrical system in the factory annually with the certification of engineers or other persons as specified by the cabinet as published in the Government Gazette. [1],[2],[3]
5 The entrepreneur of the factory business shall provide for the inspection and shall provide for electrical system maintenance and electrical products in the business place to be used safety, for at least once a year; and shall prepare for record of result of the inspection and certification of electrical system certification, and shall inform of the result to the safety inspector in charge within 15 days as from the inspection day. [1],[2],[6]
6 The entrepreneur of the factory business shall provide for regulations on actions to be made on safety, occupational health, and environment at work concerned with electrical system under the standard as specified by law, to be manual for employees. [1],[2],[4]
7 The entrepreneur of the factory business shall provide for training on employees whose work is concerned with electricity and understand skill necessary for working safely. [1],[2],[4]
8 The entrepreneur of the factory business shall provide for light in the area where the employees work that is concerned with electricity sufficiently in order to work safely. [1],[2],[4]
9 The entrepreneur of the factory business shall provide for warning signboard in the size that can easily and clearly seen to be installed in the area that may be dangerous from electric current. [1],[2],[4]
10 The entrepreneur of the factory business shall not allow the employee whose work is not involved, to access or come near the place wherer there is electric current in the distance as specified by law. [1],[2],[4]
11 The entrepreneur of the factory business shall be in charge to ensure that the employee shall not wear wet clothes or clothes which is electrical medium when performing work concerned with electric current or with electric power of more than 50 volt without insulation, except in the case when the employer arranges the employee to wear personal safety equipment with insulation appropriately already. [1],[2],[4]
12 The entrepreneur of the factory business shlall arrange the employee to work by using equipment in performing work concerned with electric current or in the area near the electic current, the employee then shall provide for equipment which is insulation for employee to work safely. [1],[2],[4]
13 The entrepreneur of the factory business shall provide for resistance of the insulation measured between the electrical line and the zero electrical line and grounded line. [1],[2],[4]
14 The entrepreneur of the factory business shall provide for pictures sheets with explanations posted at the area where the employees can see clearly, related to what to do when facing danger from electricity and first aids and life rescue by restore respiration through mouth or nose of the injured and by massaging heart from outside. [1],[2],[4]
15 The entrepreneur of the factory business shall provide for inspection and maintenance of electrical system and electrical products to be used safely for not less than once a eyar and shall prepare for record of the result of the inspecdtion in order to ready to be inspected by the labor inspector anytime. [1],[2],[4]
16 The entrepreneur of the factory business shall provide for the installation of thunderbolt prevention system at the building or at the area where there is inflammable material storage tank, under the standard of the Engineering Institute of Thailand under His Majesty the King’s Patronage. [1],[2],[4]
17 The entrepreneur of the factory business shall provide for installation of lighting rod system at the chimney which is not in the radius of protective cone of thunderbolt prevention system, the radius at the ground shall be equal to the height of lighting lod pole. [1],[2],[4]
Details
No. List of Laws Laws
2 Issues of Occupational Safety, Health And Environment ActB.E. 2554
4 Issues of Factory Act B.E. 2535
2 Issues of Other Act
1 The second-type entrepreneur of the factory business and the third-type entrepreneur of the factory business shall have drawing plan showing the installation of electrical system in the factory as actually built (as-built drawing) and particulars of the drawing; in such drawing, there shall be certification of engineers or other persons as specified by the cabinet as published in the Government Gazette.The entrepreneur of the factory business shall keep such drawing for the inspection by official. [1],[2],[3]
2 The entrepreneur of the factory business shall use material, equipment, and components of the electrical system in the factory which is characterized by Industrial Products Standard as specified by law on Industrial Product Standard or other accepted standards with the certification of engineers or other persons as specified by the cabinet as published in the Government Gazette. [1],[2],[3]
3 In using electrical sytem in the factory, the entrepreneur of the factory business shall take actions to be under the academic principle, or accepted standard or under criteria and other methods as specified by the Cabinet by publishing in the Government Gazette. [1],[2],[3]
4 The entrepreneur of the factory business shall provide for inspection of electrical system and safety certification of electrical system in the factory annually with the certification of engineers or other persons as specified by the cabinet as published in the Government Gazette. [1],[2],[3]
5 The entrepreneur of the factory business shall provide for the inspection and shall provide for electrical system maintenance and electrical products in the business place to be used safety, for at least once a year; and shall prepare for record of result of the inspection and certification of electrical system certification, and shall inform of the result to the safety inspector in charge within 15 days as from the inspection day. [1],[2],[6]
6 The entrepreneur of the factory business shall provide for regulations on actions to be made on safety, occupational health, and environment at work concerned with electrical system under the standard as specified by law, to be manual for employees. [1],[2],[4]
7 The entrepreneur of the factory business shall provide for training on employees whose work is concerned with electricity and understand skill necessary for working safely. [1],[2],[4]
8 The entrepreneur of the factory business shall provide for light in the area where the employees work that is concerned with electricity sufficiently in order to work safely. [1],[2],[4]
9 The entrepreneur of the factory business shall provide for warning signboard in the size that can easily and clearly seen to be installed in the area that may be dangerous from electric current. [1],[2],[4]
10 The entrepreneur of the factory business shall not allow the employee whose work is not involved, to access or come near the place wherer there is electric current in the distance as specified by law. [1],[2],[4]
11 The entrepreneur of the factory business shall be in charge to ensure that the employee shall not wear wet clothes or clothes which is electrical medium when performing work concerned with electric current or with electric power of more than 50 volt without insulation, except in the case when the employer arranges the employee to wear personal safety equipment with insulation appropriately already. [1],[2],[4]
12 The entrepreneur of the factory business shlall arrange the employee to work by using equipment in performing work concerned with electric current or in the area near the electic current, the employee then shall provide for equipment which is insulation for employee to work safely. [1],[2],[4]
13 The entrepreneur of the factory business shall provide for resistance of the insulation measured between the electrical line and the zero electrical line and grounded line. [1],[2],[4]
14 The entrepreneur of the factory business shall provide for pictures sheets with explanations posted at the area where the employees can see clearly, related to what to do when facing danger from electricity and first aids and life rescue by restore respiration through mouth or nose of the injured and by massaging heart from outside. [1],[2],[4]
15 The entrepreneur of the factory business shall provide for inspection and maintenance of electrical system and electrical products to be used safely for not less than once a eyar and shall prepare for record of the result of the inspecdtion in order to ready to be inspected by the labor inspector anytime. [1],[2],[4]
16 The entrepreneur of the factory business shall provide for the installation of thunderbolt prevention system at the building or at the area where there is inflammable material storage tank, under the standard of the Engineering Institute of Thailand under His Majesty the King’s Patronage. [1],[2],[4]
17 The entrepreneur of the factory business shall provide for installation of lighting rod system at the chimney which is not in the radius of protective cone of thunderbolt prevention system, the radius at the ground shall be equal to the height of lighting lod pole. [1],[2],[4]
Relavant Laws
No. List of Laws Laws
1 Factory Act, B.E.2535 (1992)
2 Occupational Safety, Health And Environment Act, B.E.2554 (2011)
3 Regulations Of The Ministry Of Industry: The Safety Measures Regarding To An Electrical System In A Factory, B.E.2550 (2007)
4 Ministerial Regulations Prescribing Standard For Administration And Management Of Occupational Safety, Health, And Environment At Workplace For Works Involving Electricity, B.E.2554 (2011)
5 Notification Of The Department Of Labor Protection And Welfare: The Criteria, Procedure And Condition For Training For Safety Working Condition For Works Involving Electricity, For Employee Working With Electricity
6 Notification Of The Department Of The Labor Protection And Welfare: The Criteria, Procedure And Condition For Preparation Of Inspection Record And Certification Of Electric Devices And System
7 Rules Of The Energy Regulatory Commission: The Standard For Connecting Devices For Electricity Grid System, Means For Verification And Assurance Of Result Of Low Pressure Grid-Connected Inverter Equipment, B.E.2559 (2016)
8 Rules Of The Energy Regulatory Commission: The Standard For Providing Of Electricity Business, Types Of Licenses For Electricity Distribution System, B.E.2559 (2016)
Forms
No. List of Forms Forms
1 The record of examination result and certifying the electrical system and equipment, Department of Labour Protection and Welfare, Ministry of Labour