3.1.5.2 Building System

Details
No. List of Laws Laws
21 Issues of Building Control Act B.E. 2522
1 Issues of The Enhancement And Conservation Of National Environmental Quality Act B.E. 2535
2 Issues of The Public Health Act B.E. 2535
1 Specify characteristics of building to be used for commerce, industry, education, and others to be controlled building. [1],[2],[3],[4],[5],[6]
2 Specify the weight support for resistance, duration, and characteristics of the material used in the construcition, modification or repair of building and weight support or the ground supporting the building. [1],[2],[3],[4],[5],[7]
3 Specity fee or exemption of fee that shall be under Ministeriral Regulation. [1],[2],[3],[4],[5],[8]
4 Specify conditions in various designs of the factory building including the characteristics of space area outside the building and along the building of air ventilation system, electrical system and fire prevention sytem, wastewater treatment system, water supply system, waste management system, and elevator system. [1],[2],[3],[4],[5],[9]
5 For the one-room building, houses in line, twin house, and building used as gathering place for the people, there shall be method concerned with fire prevention as specified in the Ministerial Regulation. [1],[2],[3],[4],[5],[10]
6 The factory building shall be installed by mobile fire-extinguisher under type and size as specified by law for extinguishing fire due to the type of material of each floor, one unit per area of not more than 1,000 square meters, for every distance of 45 meters but not less than 1 unit per floor, and the installation of fire extinguisher under paragraph one and two shall be done by allowing the top part of the unit bre higher from the floor level of not more than 1.50 meters in the the place where it is possible to read and see usage suggestions and can be applied conveniently and shall be in the good condition to be used at all times. [1],[2],[3],[4],[5],[10]
7 The factory building with the total area in all floors in the same building of more than 2,000 square meters shall have fire alarm every floor. [1],[2],[3],[4],[5],[10]
8 The factory building where the person can access to or use must have restroom or toilet of not less than the specified by law. [1],[2],[3],[4],[5],[10]
9 The septic tank of the restroom shall be far from the canal, river, or public river of not lessthan 10 metes except for the restroom with waste and dirt management system under public health system and with the appropriate size. [1],[2],[3],[4],[5],[10]
10 Various parts the building shall have light intensity of not less than that specified in the Attachment of this Ministerial Regulation. [1],[2],[3],[4],[5],[10]
11 The air ventilation system in the building can be provided with air ventilation by natural method or by mechanical method. [1],[2],[3],[4],[5],[10]
12 The position of external air and water channel by mechanical method shall be far from the waste air and air release channel of not less than 5 meters and shall be higher from ground of not les than 1.5 metes, it shall not cause annoyance to the people nearby. [1],[2],[3],[4],[5],[10]
13 In the factory, there shall be UPS such as battery or dynamo as separated independently from the system tht is currently used normally and can function automatically when normal power supply stops. [1],[2],[3],[4],[5],[10]
14 Specify forms and methods concerned with installation of fire prevention system and the number of restrooms and toilets, lighting system, air ventilation system, and UPS. [1],[2],[3],[4],[5],[10]
15 The edifice, large bulding, public building, collecting residing building, restarrant factory, and office where the condition is not safe from fire, the local authority has power to order the owner or the possessor to correct it within specified period of time but not less than 30 days, when there is reasonable cause the local official may extend such perid. [1],[2],[3],[4],[5],[11]
16 The elements or material of fire exit or main structure of the building with the height of more than 3 floors shall not be inflammable substance. [1],[2],[3],[4],[5],[12]
17 Material used for external decoration of the building or used as building wall shall be fixed with the building by the method that would not cause it to fall that may cause danger or damage. [1],[2],[3],[4],[5],[12]
18 The construction material used in the building shall not cause the suspended matter in the air that may cause danger to health such as asbestos, silica, or glass fiber unless it is covered to prevent it from spreading and or being exposed to the air. [1],[2],[3],[4],[5],[12]
19 Material which is the surface of external wall of the building or used for decoration externally shall have light reflection of not more than 30 percent. [1],[2],[3],[4],[5],[12]
20 The glass used for making external wall of the building which is edifice and large building shall be of 2 layers or more to be connected with the material in between layers and fixing the glass of each floor into one homogenous glass. It must be able to prevent or reduce danger from cutting, and the in-between matrial shall not fall off when the glass breaks. [1],[2],[3],[4],[5],[12]
21 For the land used as location nof large building or edifice with the total area of the building of all floors of more than 30,000 square meters shall have one side of the land with the length of not less than 12.00 meters connected with the public road with the wide line of not less than 18.00 meters connected to the public road with the width of not less than 18.00 meters. The land at the side connected to the public road shall be of not less than 12.00 meters wide to the area of the location of the building, and such land shall be empty space to be used as exit and entrance of the fire-extinguishing vehicle conveniently. [1],[2],[3],[4],[5],[13]
22 The large building or edifice shall be provided with the road with road surface of not less than 6.00 meters that is without coverings around the building so tht the fire-extinguishing vehicle could enter or exit conveniently. [1],[2],[3],[4],[5],[13]
23 The part which is fartherest outside of the large building or edifice shall not be less than 6.00 meters far from the other’s land or public road, excluding the foundation part of the building. [1],[2],[3],[4],[5],[13]
24 The large building or the edifice that is constructed in the land used as location of the building shall be of maximum value of the ratio of the building area in total of all floors per land area used as location of the building of not more than ratio of 10 to 1. [1],[2],[3],[4],[5],[13]
25 The commercial building, facory, public building, and other buildings that are not used as residence shall have space of not less than 10 % of the land area used as location of the building. [1],[2],[3],[4],[5],[13]
26 The large building or the edifice shall be provided with wall or door made by fire-resistance material that can bar flame or smoke when there is fire from entering into the stairs area that is not fire exit stairs of the building, such wall or the door shall be able to resist fire for not less than 1 hour. [1],[2],[3],[4],[5],[13]
27 The large building or the edifice shall be provided with the drawing of the building of each floor, kept at the hall in front of the all ift of each floor in the position where it is clearly seen, and at the ground floor there shall be building drawing every floor to be kept in order that the inspection could be performed conveniently. [1],[2],[3],[4],[5],[13]
28 The air ventilation system in the large building or the edifice can be provided with the air ventilation system by natural method or by mechanical method [1],[2],[3],[4],[5],[13]
29 The large building shall be provided with deck and the area on the deck with the size of not less than 10.00 meters of width and length, which is open area and is empty space to use as fire exit through air way and shall be provided with fire exit on the dect that would lead to the fire exit conveniently, and there shall be equipment used in fire exiting from the building to the ground safely. [1],[2],[3],[4],[5],[13]
30 The warehouse bulding that is in the Industrial Estate zone which is established under the specification of law on the Industrial Estate Authority of Thailand, with the side that is connected to the land outside the area of the Industrial Estate which is established under the law on the Industrial Estate Authority of Thailand, shall have distance far from the land used for building construction of not less than 10 meters. [1],[2],[3],[4],[5],[14]
31 The factory bulding that is in the Industrial Estate zone which is established under the specification of law on the Industrial Estate Authority of Thailand, with the side that is connected to the land outside the area of the Industrial Estate which is established under the law on the Industrial Estate Authority of Thailand, shall have distance far from the land used for building construction of not less than 10 meters. [1],[2],[3],[4],[5],[14]
32 The main structure of the building shall be constructed by the fire-ristance matiral which has characteristics and property as specified by law. [1],[2],[3],[4],[5],[15]
33 The main strucutrte which is pole constructed by steel with the structure appearance, where concrete is not used to cover by other method in order to have fire resistance rate of not less than 3 hours, and shall have certificate on the fire-resistance rate from the reliable institute together with the application for permission. [1],[2],[3],[4],[5],[15]
34 The roof structure of the building that is constructed by the steel, with the structure appearance, where concrete is not used to cover, if such building is the one-floor building,the roof structure shall have fire-resistnace rate of not less than 1 hour, and if it is the building with two or more floors, the roof structure shall have fire resistance rate of not less than 2 horus, and shall have certificate on the fire-resistance rate from the reliable institute together with the application for permission. [1],[2],[3],[4],[5],[15]
35 The roof structure of the building in the following cases shall have fire resistance rate as specified by law including (1) it is the roof structure of the building with the total area in all floors in one building of not more than 1,000 square meters except for entertainment hall, medical center or meeting hall; (2) it is the roof structure of the building which is higher from the building floor of more than 8 meters and such building shall have automatic extinguishing system or heat prevention or heat cooling system that does not cause danger to the roof structure. [1],[2],[3],[4],[5],[15]
36 The method testing the fire resistance rate shall be under ISO 838 Standard or ASTM E 119 Standard. [1],[2],[3],[4],[5],[15]
37 The construction of the building in the land of the same owner, the wall of the building with window, door, air ventilation channel, or light channel or balcony shall have distance far from other building at the side with window, door, air ventilation channel, or light channel or balcony. [1],[2],[3],[4],[5],[16]
38 The construction of the building in the land of the same owner, the wall of the building at the side which is opaque wall shall have distance from the wall of other building the side with window, door, air ventilation channel, or light channel or balcony. [1],[2],[3],[4],[5],[16]
39 The construction of the building in the land of the same owner, the wall of the building with the height of more than 15 meters but less than 23 meters, the side which is opaque wall shall be far from other building with the height of more than 15 meters but less than 23 meters at the side which is opaque of not less than 1 meter. [1],[2],[3],[4],[5],[16]
40 The toilet and the bathroom may be separated or may be in the same room with the characteristics under the specification of law; for example, it is made by durable material and the material which is easy to clean, with air ventioation channel of not lessthan 10 % of the area of room, with sufficient air ventilation fan etc. [1],[2],[3],[4],[5],[17]
41 In case when other laws specify the criteria concerned with design and method of the installation of the fire prevention system and lighting system and air ventilation system for any building in particular, such criteria as specified by law shall be applied. [1],[2],[3],[4],[5],[17]
42 The inspection of design work and the calculation of various parts of the building structure shall be done by the authorized to be the one who has profession in civil engineer under the specification of law on engineering and the inspector as mentioned shall not do the inspection of the work done by such engineer’s spouse or representative. [1],[2],[3],[4],[5],[18]
43 The inspection of design work and the calculation of various parts of the building structure shall be done by the inspector to inspect drawing and calculations on part that is concerned with building structure by taking criteria and standard into consideration a specified by law. [1],[2],[3],[4],[5],[18]
44 The law specifies other constructions built as building under the specification of law on building control include: tank with the capacity of more than 100 cubic meters, (2) swimming pool outside the buildignwith the capacity of more than 100 cubic metes, (3) wall separating soil or water shall bel able to support pressure of soil or water at the height of 1.50 meters or over, (4) structure used for receiving and sending raido or television with the height form base of the structure of 10 meters or more and shall have total weight of 40 kilograms or over, (5) other constructions besides (1), (2), (3) and (4) with the height from the base of 10 meters or more. [1],[2],[3],[4],[5],[19]
45 The law specifies standard of the vibration in order to prevent impact against the building and spedifies inspection method. [1],[2],[3],[4],[5],[24]
46 In designing building structure, the person in charge of calculation and design shall take geometric pattern into consideration to be stable and resist the vibration of earthquake in order to prevent disaster completely, the detemiantion of details of parts of structure and the connected area between the end part of various structures, and the arrangement of the entire structure to have ductility of equal to limited ductibility under standard of the design under the Department of the Public Works and Town and Country Planning, or standard on design to support vibration of earthquake as calculated by the Council of Engineers and under Building Control Act B.E. 2522 (1979). [1] - [73]
47 The calculation and the design of the structure of the building with irregular shape or other building structures and is not in the monitoring zone, the person in chrge shall be given license as professional supervising engineer of ordinary engineer level or over, and th ecalcualtion shall be done in the way that can support vibration of earthquake by using dynamics principle. [1],[2],[3],[4],[5],[20]
48 For the calculation and the design of the structure of the building which is characterized by house building, or other similar constructions and is not in the monitoring zone, the person in charge of calculation and design shall make it to be able to support vibration of earthquake by calculating shear force. [1],[2],[3],[4],[5],[20]
49 The law specifies that there shall be facilities for the disable and the elderly as specified in the Ministerial Regulation in the area opened for service to the public in the following buildings (1) hospital, medical center, public health care center, health care station, office building of the government or state enterprise, government organization established under the law, educational institute, library and government museum, mass transportation station such as airport, railway station, pier station with the area opened for service to the public for more than 300 square meters; and (2) office, entertainment hall, hotel, meeting hall, sports stadium, department stores with the area of any part of the building opened for service to the public for more than 2,000 square meters. [1],[2],[3],[4],[5],[21]
50 The signpost showing facilities for the disable and the elderly shall be clearly seen, in the position that would not cause confusion and shall be provided with extra light both during the day and at night. [1],[2],[3],[4],[5],[21]
51 If the ground level inside the building or the ground level in the building and outside the building or the level of corridor outside the building are different for more than 20 millimeters, there shall be ramp or lift between the area of different levels; but if the difference of levels of not more than 20 millimeters, the corner of the part of the floor that is diferrent in level shall be cut to be of not more than 45 degrees. [1],[2],[3],[4],[5],[21]
52 The building with the number of floors of two floors or more shall be provided with lift or ramp that can be used by the disable and the elderly between the floor of the building, the lift to be used by the disable and the elderly shall be able to go up and down every floor with lift control system that the disable and the elderly can use by themselves safety, and shall be provided in the area where the disable and the elderly can use conveniently and clearly. [1],[2],[3],[4],[5],[21]
53 The law specifies that the building shall be provided with the stairs for the disable and the elderly to use for at least 1 site per floor and there shall be parking place for the disable and the elderly under the ratio as specified by law. [1],[2],[3],[4],[5],[21]
54 The law specifies the building shall be provided with building entry so that the disable and the elderly can use, which is characterized by that contained in the specification of law. [1],[2],[3],[4],[5],[21]
55 The law specifies that the building shall be provided with restroom for general people, there shall be restroom for the disable and the elderly at least 1 room in such restroom, or it may be separated in the same area with the restroom for general people. [1],[2],[3],[4],[5],[21]
56 The residing building where there are more than one construction workers per 3 squaremeters is considered as too much. [1],[2],[3],[4],[5],[22]
57 The factory building where there are more than one construction workers per 3 squaremeters is considered as too much. [1],[2],[3],[4],[5],[23]
Details
No. List of Laws Laws
21 Issues of Building Control Act B.E. 2522
1 Issues of The Enhancement And Conservation Of National Environmental Quality Act B.E. 2535
2 Issues of The Public Health Act B.E. 2535
1 Specify characteristics of building to be used for commerce, industry, education, and others to be controlled building. [1],[2],[3],[4],[5],[6]
2 Specify the weight support for resistance, duration, and characteristics of the material used in the construcition, modification or repair of building and weight support or the ground supporting the building. [1],[2],[3],[4],[5],[7]
3 Specity fee or exemption of fee that shall be under Ministeriral Regulation. [1],[2],[3],[4],[5],[8]
4 Specify conditions in various designs of the factory building including the characteristics of space area outside the building and along the building of air ventilation system, electrical system and fire prevention sytem, wastewater treatment system, water supply system, waste management system, and elevator system. [1],[2],[3],[4],[5],[9]
5 For the one-room building, houses in line, twin house, and building used as gathering place for the people, there shall be method concerned with fire prevention as specified in the Ministerial Regulation. [1],[2],[3],[4],[5],[10]
6 The factory building shall be installed by mobile fire-extinguisher under type and size as specified by law for extinguishing fire due to the type of material of each floor, one unit per area of not more than 1,000 square meters, for every distance of 45 meters but not less than 1 unit per floor, and the installation of fire extinguisher under paragraph one and two shall be done by allowing the top part of the unit bre higher from the floor level of not more than 1.50 meters in the the place where it is possible to read and see usage suggestions and can be applied conveniently and shall be in the good condition to be used at all times. [1],[2],[3],[4],[5],[10]
7 The factory building with the total area in all floors in the same building of more than 2,000 square meters shall have fire alarm every floor. [1],[2],[3],[4],[5],[10]
8 The factory building where the person can access to or use must have restroom or toilet of not less than the specified by law. [1],[2],[3],[4],[5],[10]
9 The septic tank of the restroom shall be far from the canal, river, or public river of not lessthan 10 metes except for the restroom with waste and dirt management system under public health system and with the appropriate size. [1],[2],[3],[4],[5],[10]
10 Various parts the building shall have light intensity of not less than that specified in the Attachment of this Ministerial Regulation. [1],[2],[3],[4],[5],[10]
11 The air ventilation system in the building can be provided with air ventilation by natural method or by mechanical method. [1],[2],[3],[4],[5],[10]
12 The position of external air and water channel by mechanical method shall be far from the waste air and air release channel of not less than 5 meters and shall be higher from ground of not les than 1.5 metes, it shall not cause annoyance to the people nearby. [1],[2],[3],[4],[5],[10]
13 In the factory, there shall be UPS such as battery or dynamo as separated independently from the system tht is currently used normally and can function automatically when normal power supply stops. [1],[2],[3],[4],[5],[10]
14 Specify forms and methods concerned with installation of fire prevention system and the number of restrooms and toilets, lighting system, air ventilation system, and UPS. [1],[2],[3],[4],[5],[10]
15 The edifice, large bulding, public building, collecting residing building, restarrant factory, and office where the condition is not safe from fire, the local authority has power to order the owner or the possessor to correct it within specified period of time but not less than 30 days, when there is reasonable cause the local official may extend such perid. [1],[2],[3],[4],[5],[11]
16 The elements or material of fire exit or main structure of the building with the height of more than 3 floors shall not be inflammable substance. [1],[2],[3],[4],[5],[12]
17 Material used for external decoration of the building or used as building wall shall be fixed with the building by the method that would not cause it to fall that may cause danger or damage. [1],[2],[3],[4],[5],[12]
18 The construction material used in the building shall not cause the suspended matter in the air that may cause danger to health such as asbestos, silica, or glass fiber unless it is covered to prevent it from spreading and or being exposed to the air. [1],[2],[3],[4],[5],[12]
19 Material which is the surface of external wall of the building or used for decoration externally shall have light reflection of not more than 30 percent. [1],[2],[3],[4],[5],[12]
20 The glass used for making external wall of the building which is edifice and large building shall be of 2 layers or more to be connected with the material in between layers and fixing the glass of each floor into one homogenous glass. It must be able to prevent or reduce danger from cutting, and the in-between matrial shall not fall off when the glass breaks. [1],[2],[3],[4],[5],[12]
21 For the land used as location nof large building or edifice with the total area of the building of all floors of more than 30,000 square meters shall have one side of the land with the length of not less than 12.00 meters connected with the public road with the wide line of not less than 18.00 meters connected to the public road with the width of not less than 18.00 meters. The land at the side connected to the public road shall be of not less than 12.00 meters wide to the area of the location of the building, and such land shall be empty space to be used as exit and entrance of the fire-extinguishing vehicle conveniently. [1],[2],[3],[4],[5],[13]
22 The large building or edifice shall be provided with the road with road surface of not less than 6.00 meters that is without coverings around the building so tht the fire-extinguishing vehicle could enter or exit conveniently. [1],[2],[3],[4],[5],[13]
23 The part which is fartherest outside of the large building or edifice shall not be less than 6.00 meters far from the other’s land or public road, excluding the foundation part of the building. [1],[2],[3],[4],[5],[13]
24 The large building or the edifice that is constructed in the land used as location of the building shall be of maximum value of the ratio of the building area in total of all floors per land area used as location of the building of not more than ratio of 10 to 1. [1],[2],[3],[4],[5],[13]
25 The commercial building, facory, public building, and other buildings that are not used as residence shall have space of not less than 10 % of the land area used as location of the building. [1],[2],[3],[4],[5],[13]
26 The large building or the edifice shall be provided with wall or door made by fire-resistance material that can bar flame or smoke when there is fire from entering into the stairs area that is not fire exit stairs of the building, such wall or the door shall be able to resist fire for not less than 1 hour. [1],[2],[3],[4],[5],[13]
27 The large building or the edifice shall be provided with the drawing of the building of each floor, kept at the hall in front of the all ift of each floor in the position where it is clearly seen, and at the ground floor there shall be building drawing every floor to be kept in order that the inspection could be performed conveniently. [1],[2],[3],[4],[5],[13]
28 The air ventilation system in the large building or the edifice can be provided with the air ventilation system by natural method or by mechanical method [1],[2],[3],[4],[5],[13]
29 The large building shall be provided with deck and the area on the deck with the size of not less than 10.00 meters of width and length, which is open area and is empty space to use as fire exit through air way and shall be provided with fire exit on the dect that would lead to the fire exit conveniently, and there shall be equipment used in fire exiting from the building to the ground safely. [1],[2],[3],[4],[5],[13]
30 The warehouse bulding that is in the Industrial Estate zone which is established under the specification of law on the Industrial Estate Authority of Thailand, with the side that is connected to the land outside the area of the Industrial Estate which is established under the law on the Industrial Estate Authority of Thailand, shall have distance far from the land used for building construction of not less than 10 meters. [1],[2],[3],[4],[5],[14]
31 The factory bulding that is in the Industrial Estate zone which is established under the specification of law on the Industrial Estate Authority of Thailand, with the side that is connected to the land outside the area of the Industrial Estate which is established under the law on the Industrial Estate Authority of Thailand, shall have distance far from the land used for building construction of not less than 10 meters. [1],[2],[3],[4],[5],[14]
32 The main structure of the building shall be constructed by the fire-ristance matiral which has characteristics and property as specified by law. [1],[2],[3],[4],[5],[15]
33 The main strucutrte which is pole constructed by steel with the structure appearance, where concrete is not used to cover by other method in order to have fire resistance rate of not less than 3 hours, and shall have certificate on the fire-resistance rate from the reliable institute together with the application for permission. [1],[2],[3],[4],[5],[15]
34 The roof structure of the building that is constructed by the steel, with the structure appearance, where concrete is not used to cover, if such building is the one-floor building,the roof structure shall have fire-resistnace rate of not less than 1 hour, and if it is the building with two or more floors, the roof structure shall have fire resistance rate of not less than 2 horus, and shall have certificate on the fire-resistance rate from the reliable institute together with the application for permission. [1],[2],[3],[4],[5],[15]
35 The roof structure of the building in the following cases shall have fire resistance rate as specified by law including (1) it is the roof structure of the building with the total area in all floors in one building of not more than 1,000 square meters except for entertainment hall, medical center or meeting hall; (2) it is the roof structure of the building which is higher from the building floor of more than 8 meters and such building shall have automatic extinguishing system or heat prevention or heat cooling system that does not cause danger to the roof structure. [1],[2],[3],[4],[5],[15]
36 The method testing the fire resistance rate shall be under ISO 838 Standard or ASTM E 119 Standard. [1],[2],[3],[4],[5],[15]
37 The construction of the building in the land of the same owner, the wall of the building with window, door, air ventilation channel, or light channel or balcony shall have distance far from other building at the side with window, door, air ventilation channel, or light channel or balcony. [1],[2],[3],[4],[5],[16]
38 The construction of the building in the land of the same owner, the wall of the building at the side which is opaque wall shall have distance from the wall of other building the side with window, door, air ventilation channel, or light channel or balcony. [1],[2],[3],[4],[5],[16]
39 The construction of the building in the land of the same owner, the wall of the building with the height of more than 15 meters but less than 23 meters, the side which is opaque wall shall be far from other building with the height of more than 15 meters but less than 23 meters at the side which is opaque of not less than 1 meter. [1],[2],[3],[4],[5],[16]
40 The toilet and the bathroom may be separated or may be in the same room with the characteristics under the specification of law; for example, it is made by durable material and the material which is easy to clean, with air ventioation channel of not lessthan 10 % of the area of room, with sufficient air ventilation fan etc. [1],[2],[3],[4],[5],[17]
41 In case when other laws specify the criteria concerned with design and method of the installation of the fire prevention system and lighting system and air ventilation system for any building in particular, such criteria as specified by law shall be applied. [1],[2],[3],[4],[5],[17]
42 The inspection of design work and the calculation of various parts of the building structure shall be done by the authorized to be the one who has profession in civil engineer under the specification of law on engineering and the inspector as mentioned shall not do the inspection of the work done by such engineer’s spouse or representative. [1],[2],[3],[4],[5],[18]
43 The inspection of design work and the calculation of various parts of the building structure shall be done by the inspector to inspect drawing and calculations on part that is concerned with building structure by taking criteria and standard into consideration a specified by law. [1],[2],[3],[4],[5],[18]
44 The law specifies other constructions built as building under the specification of law on building control include: tank with the capacity of more than 100 cubic meters, (2) swimming pool outside the buildignwith the capacity of more than 100 cubic metes, (3) wall separating soil or water shall bel able to support pressure of soil or water at the height of 1.50 meters or over, (4) structure used for receiving and sending raido or television with the height form base of the structure of 10 meters or more and shall have total weight of 40 kilograms or over, (5) other constructions besides (1), (2), (3) and (4) with the height from the base of 10 meters or more. [1],[2],[3],[4],[5],[19]
45 The law specifies standard of the vibration in order to prevent impact against the building and spedifies inspection method. [1],[2],[3],[4],[5],[24]
46 In designing building structure, the person in charge of calculation and design shall take geometric pattern into consideration to be stable and resist the vibration of earthquake in order to prevent disaster completely, the detemiantion of details of parts of structure and the connected area between the end part of various structures, and the arrangement of the entire structure to have ductility of equal to limited ductibility under standard of the design under the Department of the Public Works and Town and Country Planning, or standard on design to support vibration of earthquake as calculated by the Council of Engineers and under Building Control Act B.E. 2522 (1979). [1] - [73]
47 The calculation and the design of the structure of the building with irregular shape or other building structures and is not in the monitoring zone, the person in chrge shall be given license as professional supervising engineer of ordinary engineer level or over, and th ecalcualtion shall be done in the way that can support vibration of earthquake by using dynamics principle. [1],[2],[3],[4],[5],[20]
48 For the calculation and the design of the structure of the building which is characterized by house building, or other similar constructions and is not in the monitoring zone, the person in charge of calculation and design shall make it to be able to support vibration of earthquake by calculating shear force. [1],[2],[3],[4],[5],[20]
49 The law specifies that there shall be facilities for the disable and the elderly as specified in the Ministerial Regulation in the area opened for service to the public in the following buildings (1) hospital, medical center, public health care center, health care station, office building of the government or state enterprise, government organization established under the law, educational institute, library and government museum, mass transportation station such as airport, railway station, pier station with the area opened for service to the public for more than 300 square meters; and (2) office, entertainment hall, hotel, meeting hall, sports stadium, department stores with the area of any part of the building opened for service to the public for more than 2,000 square meters. [1],[2],[3],[4],[5],[21]
50 The signpost showing facilities for the disable and the elderly shall be clearly seen, in the position that would not cause confusion and shall be provided with extra light both during the day and at night. [1],[2],[3],[4],[5],[21]
51 If the ground level inside the building or the ground level in the building and outside the building or the level of corridor outside the building are different for more than 20 millimeters, there shall be ramp or lift between the area of different levels; but if the difference of levels of not more than 20 millimeters, the corner of the part of the floor that is diferrent in level shall be cut to be of not more than 45 degrees. [1],[2],[3],[4],[5],[21]
52 The building with the number of floors of two floors or more shall be provided with lift or ramp that can be used by the disable and the elderly between the floor of the building, the lift to be used by the disable and the elderly shall be able to go up and down every floor with lift control system that the disable and the elderly can use by themselves safety, and shall be provided in the area where the disable and the elderly can use conveniently and clearly. [1],[2],[3],[4],[5],[21]
53 The law specifies that the building shall be provided with the stairs for the disable and the elderly to use for at least 1 site per floor and there shall be parking place for the disable and the elderly under the ratio as specified by law. [1],[2],[3],[4],[5],[21]
54 The law specifies the building shall be provided with building entry so that the disable and the elderly can use, which is characterized by that contained in the specification of law. [1],[2],[3],[4],[5],[21]
55 The law specifies that the building shall be provided with restroom for general people, there shall be restroom for the disable and the elderly at least 1 room in such restroom, or it may be separated in the same area with the restroom for general people. [1],[2],[3],[4],[5],[21]
56 The residing building where there are more than one construction workers per 3 squaremeters is considered as too much. [1],[2],[3],[4],[5],[22]
57 The factory building where there are more than one construction workers per 3 squaremeters is considered as too much. [1],[2],[3],[4],[5],[23]
Relavant Laws
No. List of Laws Laws
1 Building Control Act, B.E.2522 (1979)
2 Building Control Act (No.2), B.E.2535 (1992)
3 Building Control Act (No.3), B.E.2543 (2000)
4 Building Control Act (No.4), B.E.2550 (2007)
5 Building Control Act (No.5), B.E.2558 (2015)
6 Ministerial Regulation, B.E.2524 (1981), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
7 Ministerial Regulation No.2, B.E.2524 (1981), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
8 Ministerial Regulation No.3, B.E.2526 (1983), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
9 Ministerial Regulation No.4, B.E.2526 (1983), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
10 Ministerial Regulation No.5, B.E.2527 (1984), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
11 Ministerial Regulation No.6, B.E.2527 (1984), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
12 Ministerial Regulation No.7, B.E.2528 (1985), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
13 Ministerial Regulation No.8, B.E.2528 (1985), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
14 Ministerial Regulation No.9, B.E.2528 (1985), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
15 Ministerial Regulation No.11, B.E.2528 (1985), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
16 Ministerial Regulation No.12, B.E.2528 (1985), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
17 Ministerial Regulation No.13, B.E.2528 (1985), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
18 Ministerial Regulation No.14, B.E.2529 (1986), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
19 Ministerial Regulation No.15, B.E.2529 (1986), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
20 Ministerial Regulation No.16, B.E.2530 (1987), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
21 Ministerial Regulation No.17, B.E.2530 (1987), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
22 Ministerial Regulation No.18, B.E.2530 (1987), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
23 Ministerial Regulation No.19, B.E.2531 (1988), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
24 Ministerial Regulation No.20, B.E.2532 (1989), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
25 Ministerial Regulation No.21, B.E.2532 (1989), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
26 Ministerial Regulation No.22, B.E.2532 (1989), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
27 Ministerial Regulation No.23, B.E.2533 (1990), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
28 Ministerial Regulation No.24, B.E.2533 (1990), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
29 Ministerial Regulation No.25, B.E.2533 (1990), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
30 Ministerial Regulation No.26, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
31 Ministerial Regulation No.27, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
32 Ministerial Regulation No.28, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
33 Ministerial Regulation No.29, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
34 Ministerial Regulation No.30, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
35 Ministerial Regulation No.31, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
36 Ministerial Regulation No.32, B.E.2534 (1991), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
37 Ministerial Regulation No.33, B.E.2535 (1992), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
38 Ministerial Regulation No.34, B.E.2535 (1992), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
39 Ministerial Regulation No.35, B.E.2535 (1992), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
40 Ministerial Regulation No.36, B.E.2535 (1992), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
41 Ministerial Regulation No.37, B.E.2535 (1992), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
42 Ministerial Regulation No.38, B.E.2536 (1993), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
43 Ministerial Regulation No.39, B.E.2537 (1994), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
44 Ministerial Regulation No.40, B.E.2537 (1994), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
45 Ministerial Regulation No.41, B.E.2537 (1994), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
46 Ministerial Regulation No.42, B.E.2537 (1994), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
47 Ministerial Regulation No.43, B.E.2537 (1994), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
48 Ministerial Regulation No.44, B.E.2538 (1995), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
49 Ministerial Regulation No.45, B.E.2538 (1995), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
50 Ministerial Regulation No.46, B.E.2540 (1997), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
51 Ministerial Regulation No.47, B.E.2540 (1997), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
52 Ministerial Regulation No.48, B.E.2540 (1997), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
53 Ministerial Regulation No.50, B.E.2540 (1997), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
54 Ministerial Regulation No.51, B.E.2541 (1998), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
55 Ministerial Regulation No.52, B.E.2542 (1999), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
56 Ministerial Regulation No.53, B.E.2542 (1999), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
57 Ministerial Regulation No.54, B.E.2542 (1999), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
58 Ministerial Regulation No.55, B.E.2543 (2000), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
59 Ministerial Regulation No.56, B.E.2543 (2000), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
60 Ministerial Regulation No.57, B.E.2544 (2001), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
61 Ministerial Regulation No.58, B.E.2546 (2003), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
62 Ministerial Regulation No.59, B.E.2548 (2005), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
63 Ministerial Regulation No.60, B.E.2549 (2006), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
64 Ministerial Regulation No.61, B.E.2550 (2007), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
65 Ministerial Regulation No.62, B.E.2550 (2007), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
66 Ministerial Regulation No.63, B.E.2551 (2008), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
67 Ministerial Regulation No.64, B.E.2555 (2012), Issued In Accordance With The Building Control Act, B.E.2522 (1979)
68 Ministerial Regulation: Type Or Categories Of Building, Criteria, Procedure, And Condition On Inspection Of Design Calculation For A Building Structure, B.E.2550 (2007)
69 Ministerial Regulation: Definition Of Other Constructions Defined As A Building Issued In Accordance With The Building Control Act, B.E.2544 (2001)
70 Notification Of The National Environmental Board No.37, B.E.2553 (2010): The Standard Level Of Vibration To Protect The Impacts On Buildings
71 Notification Of Pollution Control Department: The Calculating Of Utility Space, Number Of Buildings, Number Of Rooms In Building Or Building Group And The Collecting Method Of Water Sampling
72 Ministerial Regulations: The Weight Bearing Capacity, Resistance, Durability Of Building And Its Supporting Ground For Vibration Of Earthquake, B.E.2550 (2007)
73 Ministerial Regulations: The Building Facilities For Disable Or Handicapped Person And Elderly, B.E.2548 (2005)
74 Notification Of The Ministry Of Public Health No.7/2538 (1995): Quantity Of Population Per Unit Area In Overcrowded Residential Building For Construction Workers
75 Notification Of The Ministry Of Public Health No.8/2538 (1995): Quantity Of Population Per Unit Area In Overcrowded Factory Building